Hazardous Area Computers from Computer Dynamics

The function of hazardous area computers and monitors is to provide computer controls or information while preventing or containing an explosion.

To allow for operator interface in hazardous environments, specially designed hazardous area computers or monitors must be utilized. Hazardous environments usually contain amounts of explosive gases or dust either during normal operation or during an abnormal circumstance. The function of hazardous area computers and monitors is to provide computer controls or information while preventing or containing an explosion. This can be accomplished by protecting the operator interface system from its environment, or protecting the environment from the operator interface system.

Hazardous area computers and monitors must comply with some of the most stringent safety guidelines defined by worldwide regulatory agencies. To increase the potential for global marketability, the United States has incorporated the IEC (International Electrotechnical Commission) Zone system into a parallel classification system to the traditional U.S. Class I Division system -- the U.S. Class I Zone system. The key concepts of the IEC system include area classification, gas grouping, temperature codes, protection methods and markings. Under both the Division and Zone systems, hazardous area computers for use in explosive gas atmospheres are identified based on designations that address:

  • The likelihood that the explosive gas atmosphere is present when hazardous area computers or monitors are operating (see the Division and Zone designations in Table 1);

  • The ignition-related properties of the explosive gas atmosphere (see the Gas Group designations in Table 2);

  • The maximum surface temperature of the equipment under normal operating conditions (see the Temperature Code designations in Table 3); and

  • The protection method(s) used by the equipment to prevent ignition of the surrounding atmosphere (see the Protection Method designations in Table 4).


Class I Area Classification Comparison

Division 1
Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operating conditions.

Zone 0
Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or for long periods of time under normal operating conditions.

Zone 1
Where ignitable concentrations of flammable gases, vapors or liquids can exist some of the time under normal operating conditions.

Division 2
Where ignitable concentrations of flammable gases, vapors or liquids are not likely to exist under normal operating conditions.

Zone 2
Where ignitable concentrations of flammable gases, vapors or liquids are not likely to exist under normal operating conditions.

Back

Class I Gas Group Comparison

Divisions 1 and 2
Zones 0, 1, 2
A
(acetylene)
IIC
(acetylene & hydrogen)
B
(hydrogen)
C
(ethylene)
IIB
(ethylene)
D
(propane)
IIA
(propane)
Back
Class I Temperature Code Comparison
Divisions 1 and 2
Zones 0, 1, 2
T1 (≤450°C) T1 (≤450°C)
T2 (≤300°C) T2 (≤300°C)
T2A, B, C, D
(280°, 260°, 230°, 215°C)
T3 (≤200°C) T3 (≤200°C)
T3A, B, C
(180°, 165°, 160°C)
T4 (≤135°C) T4 (≤135°C)
T4A (≤120°C)
T5 (≤100°C) T5 (≤100°C)
T6 (≤85°C) T6 (≤85°C)
Back

Class I Protection Method Comparison

Div. Division Protection Methods Zone Zone Protection Methods
1 Explosion-proof
Intrinsically safe (2 fault)
Purged/pressurized
(Type X or Y)
0 Intrinsically safe, 'ia' (2 fault)
Class I, Div. 1 Intrinsically safe
(2 fault)
1 Encapsulation, 'm'
Flameproof, 'd'
Increased safety, 'e'
Intrinsically safe, 'ib' (1 fault)
Oil immersion, 'o'
Powder filling, 'q' Purged/pressurized, 'p'
Any Class I, Zone 0 method
Any Class I, Division 1 method
2 Hermetically sealed
Non-incendive
Non-sparking
Oil immersion
Purged/pressurized (Type Z)
Sealed device
Any Class I, Div. 1
method
2 Hermetically sealed, 'nC'
Non-incendive, 'nC'
Non-sparking, 'nA'
Restricted breathing, 'nR'
Sealed device, 'nC'
Any Class I, Zone 0 or 1 method
Any Class I, Div. 1 or 2 method
Back to Top
Computer Dynamics, Inc., 7640 Pelham Road, Greenville, SC 29615
864-627-8800 (phone); 864-675-0106 (fax); CDIsales@gefanuc.com (general e-mail); www.cdynamics.com
Computer Dynamics manufactures hazardous area computers and monitors for the numerous work environments in demand of versatile, yet reliable operator interfaces.